Configure connection to Bonita Engine
Learn how to configure your application to connect to a remote Bonita Engine, in order to access Engine APIs
If you want your application to use Bonita Engine APIs of a remote engine, your application (the client) must configure the connection to the remote engine (the server)
The engine (the server) must also be configured to accept the connection.
Client configuration
There is three ways to configure the client to connect to the Bonita Engine.
First the engine client verify if the configuration is set programmatically, then it tries to get the configuration set in system properties, finally it falls back to the legacy way of configuration that is the bonita home client.
Configure Client using programmatic configuration
You can configure the connection to the engine directly using org.bonitasoft.engine.util.APITypeManager
, please refer to the Javadoc.
Here is an example of programmatic configuration to an engine
HashMap<String,String> parameters= new HashMap<>();
parameters.put("server.url", "http://myserver.com:8080");
parameters.put("application.name", "bonita-application");
APITypeManager.setAPITypeAndParams(ApiAccessType.HTTP, parameters)
Configure Client using System properties
You can set the system property org.bonitasoft.engine.api-type
to HTTP
or LOCAL
.
-
HTTP
: TheHTTP
connection mode will connect the client to the engine using the http protocol. This is the most common way to connect to engine remotely.
When usingHTTP
mode, you must set the following system properties-
org.bonitasoft.engine.api-type.server.url
: it is the url of the server, e.g. for a engine on the same host it can behttp://localhost:8080
-
org.bonitasoft.engine.api-type.application.name
: it is the name of the web application on which the engine HTTP API is deployed, e.g.bonita
In addition, starting from version 7.9.4, the number of connections used by the client can be configured with system property
org.bonitasoft.engine.api-type.connections.max
, the default is 20. -
We do not guarantee to keep the http protocol stable, so we strongly recommend that you use the same version for both the client and the server |
-
LOCAL
This is the default connection mode, it connects to the server in the same JVM (not remote). If nothing is set this mode will be used.
Configure client using Bonita Home client
Deprecated, use the programmatic way instead, see APITypeManager. |
This is a legacy way to configure the connection to the remote engine.
In this case you have to create a folder containing a engine-client
directory and a conf
subdirectory.
This last subdirectory must contain a file named bonita-client-custom.properties
having as content configuration of the engine client (see below).
Finally set the System property bonita.home
to the root folder you created.
Here is the default content of this configuration file, uncomment the part of the file corresponding to the type of connection you want and customize it according to your application.
###template file
# LOCAL
org.bonitasoft.engine.api-type = LOCAL
# HTTP
#org.bonitasoft.engine.api-type = HTTP
#server.url = http://localhost:8080
#application.name = bonita
#connections.max = 20
Server configuration
Server configuration to accept HTTP Connection
By default, the Tomcat bundle is configured to accept connection over HTTP.
To deactivate HTTP connections:
-
either add a Java system property
-Dhttp.api=false
to filesetEnv.[sh|bat]
inside tomcat bundle (in foldersetup/tomcat_templates/
) -
or set an environment variable
HTTP_API=false
before launching Bonita Tomcat bundle
This HTTP access is not secured, it should not be exposed outside a trusted area. We recommend you to deactivate it if you expose directly your deployment to outside your company’s networks. |