OpenID Connect SSO configuration
Bonita can be configured to use the OpenID Connect (OIDC) protocol to provide single sign-on (SSO), as long as you already have an OpenID Connect Identity Provider server up and running (IdP). OIDC is an extension of OAuth 2.0. Contrary to the SSO support of SAML2, both Bonita Web User Interface and Bonita REST API can be secured and accessed using the OIDC/OAuth protocols (versus just the Web User Interface for SAML2).
For Enterprise, Performance, Efficiency, and Teamwork editions only. |
This information applies to a Bonita platform deployed from a bundle, not to the Engine launched from Bonita Studio. <BUNDLE_HOME>
refers to the root directory of the bundle.
OpenID Connect configuration is at tenant level.
Bonita uses Keycloak OIDC Service client adapter. It has been extended to support other OIDC providers than Keycloak. |
OpenID Connect overview for Bonita
Only the Authorization Code Flow of OpenID Connect (with or without refresh token) is supported. Not the Implicit Flow.
This is an overview that describes the steps of the authentication process on a Bonita bundle configured as an OIDC client:
Here are some details about the Bonita OIDC module, it is composed of:
-
A servlet filter that intercepts all the requests to Bonita Application pages
It checks if the user is already logged in on Bonita
-
If already logged in => Allow the access
-
If not logged in => Redirect to IdP (with scope, client Id, redirect URI, and
code
response type)
-
-
An Implementation of the Authentication Manager extension point that retrieves the authentication information in the requests to log in to Bonita engine with the right credentials.
The |
Configure Bonita Bundle for OIDC
You need to execute the following actions in the folder of each tenant for which you want to support authentication over OpenID Connect.
If you want this configuration to also apply to each tenant created later, make sure to also perform those actions in the template tenant configuration folder:
<BUNDLE_HOME>/setup/platform_conf/current/tenant_template_*
(if you have not started the Bonita bundle yet, the files are located in <BUNDLE_HOME>/setup/platform_conf/initial/tenant_template_*
)
The bundle already contains the files needed to use OIDC with Bonita platform. To configure Bonita for OIDC:
-
If you do not already have one:
-
Download a Subscription edition bundle from the Customer Service Center
-
Configure it as needed
-
Run it a first time, so that the first default tenant is created (TENANT_ID = 1)
-
Stop it and run
setup[.sh][.bat] pull
to retrieve current configuration before modifying the configuration files below
-
-
In the tenant_portal folder of each existing tenant:
<BUNDLE_HOME>/setup/platform_conf/current/tenants/<TENANT_ID>/tenant_portal
, edit theauthenticationManager-config.properties
as follows:--> #auth.AuthenticationManager = org.bonitasoft.console.common.server.auth.impl.standard.StandardAuthenticationManagerImpl (...) --> auth.AuthenticationManager = org.bonitasoft.console.common.server.auth.impl.oidc.OIDCAuthenticationManagerImpl --> oidc.filter.active = true --> oidc.auth.standard.allowed = true --> oidc.logout.url = http://localhost:9090/auth/realms/bonita/protocol/openid-connect/logout --> oidc.logout.url.redirectQuery = ?post_logout_redirect_uri={encodedRedirectUri}&id_token_hint={idToken} --> auth.tenant.admin.username = install --> auth.passphrase = BonitaBPM (...) --> auth.tenant.standard.whitelist = william.jobs (...) --> logout.link.hidden=true
Make sure to set the right tenant admin username. It is recommended to also replace the value of the passphrase (property
auth.passphrase
) which is used by the engine to verify the authentication request. The value must be the same as in the file bonita-tenant-sp-custom.properties.
If you need users to be able to log in without having an account on the IDP, you can authorize it by setting the propertyoidc.auth.standard.allowed
to true. Users will then be able to log in using the Bonita login page (/login.jsp
) provided they have a Bonita account and their password is different from their username.
If only a limited group of users need to bypass OIDC authentication method you can restrain it by setting the propertyoidc.auth.standard.allowed
to false and setting the propertyauth.tenant.standard.whitelist
with the list of authorized usernames (comma separated). Otherwise you can keep it commented.
Only if you want Bonita logout to perform OpenID logout you can uncomment and configure the propertiesoidc.logout.url
andoidc.logout.url.redirectQuery
. See the Configure logout behavior section for more details about logout. -
In the tenant_engine folder of the existing tenant:
<BUNDLE_HOME>/setup/platform_conf/current/tenants/<TENANT_ID>/tenant_engine/
edit the file bonita-tenant-sp-custom.properties as follows:# Authentication service to use. Some are natively provided: # authenticationService # * binded to bonita authentication mode # * impl: org.bonitasoft.engine.authentication.impl.AuthenticationServiceImpl # jaasAuthenticationService # * to use JAAS # * impl: com.bonitasoft.engine.authentication.impl.JAASGenericAuthenticationServiceImpl # * this is the one to configure SSO over CAS (CAS properties to be defined hereafter # noAuthenticationService # * does no authentication on the engine side # * impl: com.bonitasoft.engine.authentication.impl.NoAuthenticationServiceImpl # passphraseOrPasswordAuthenticationService # * Used by SSO implementations, login only if a passphrase is valid, or if a username/password is valid. # * Requires PassphraseOrPasswordAuthenticationService bean to be uncommented in bonita-tenant-sp-custom.xml # * impl: com.bonitasoft.engine.authentication.impl.PassphraseOrPasswordAuthenticationService # you can provide your own implementation in bonita-tenant-sp-custom.xml and refer to the bean name of your choice --> authentication.service.ref.name=passphraseOrPasswordAuthenticationService # If authentication.service.ref.name equals "passphraseOrPasswordAuthenticationService", # you need to configure the following passphrase --> authentication.service.ref.passphrase=BonitaBPM # Create users on the fly, when they are missing from bonita but authenticated by the SSO. The user will belong to the group and role specified below. #authentication.passphraseOrPasswordAuthenticationService.createMissingUser.enable=true #authentication.passphraseOrPasswordAuthenticationService.createMissingUser.defaultMembershipGroupPath=/acmr/hr #authentication.passphraseOrPasswordAuthenticationService.createMissingUser.defaultMembershipRoleName=member # CAS authentication delegate : enables the user, providing login/password, # to be logged in automatically against CAS web application # To be used in conjunction with the generic authentication service configured with CAS (jaasAuthenticationService) #authenticator.delegate=casAuthenticatorDelegate #authentication.delegate.cas.server.url.prefix=http://ip_address:port #authentication.delegate.cas.service.url=http://ip_address:port/bonita/loginservice
It is recommended to also replace the value of the passphrase (property auth.passphrase). The value must be the same as in the file authenticationManager-config.properties updated previously.
If you want Bonita engine to create the accounts on the fly once a user accessing Bonita has been authenticated with the IdP, you can uncomment the property
authentication.passphraseOrPasswordAuthenticationService.createMissingUser.enable
(and set its value to true) as well as the next 2 properties to add a default membership to each user account:-
authentication.passphraseOrPasswordAuthenticationService.createMissingUser.defaultMembershipGroupPath
specify the group in which every user account created on the fly will be added (the full group path is needed) -
authentication.passphraseOrPasswordAuthenticationService.createMissingUser.defaultMembershipRoleName
specify the role to use to create the membership
Activating this option means any user authorized by the IdP to access Bonita will have an account created automatically in Bonita Database. -
-
In the tenant_portal folder of the existing tenant:
<BUNDLE_HOME>/setup/platform_conf/current/tenants/<TENANT_ID>/tenant_portal
,
edit the file keycloak-oidc.json to setup Bonita webapp as an OIDC client working with your OIDC provider.{ "realm": "master", "resource": "bonita", "auth-server-url": "http://localhost:9090/auth", "auth-url": "{auth-server-url}/realms/{realm-name}/protocol/openid-connect/auth", "token-url": "{auth-server-url}/realms/{realm-name}/protocol/openid-connect/token", "logout-url": "{auth-server-url}/realms/{realm-name}/protocol/openid-connect/logout", "token-issuer-uri": "{auth-server-url}/realms/{realm-name}", "user-info-url": "{auth-server-url}/realms/{realm-name}/protocol/openid-connect/userinfo", "jwks-url": "{auth-server-url}/realms/{realm-name}/protocol/openid-connect/certs", "jwt-access-token": true, "scope-values": "openid profile email", "save-target-url-in-state": true, "ssl-required": "external", "principal-attribute": "preferred_username", "public-client": false, "autodetect-bearer-only": true, "enable-cors": true, "cors-allowed-methods": "POST, PUT, DELETE, GET", "credentials" : { "secret" : "put-your-secret-here" } }
-
The property
realm
is only required if you use a Keycloak server as OIDC provider or if you want to benefit from the templating in the*-url
properties ({realm-name} will be replaced with the realm value). If you use a Keycloak server, make sure you set it with the name of the realm in which your Bonita OIDC client is/will be created. -
resource
is the OIDC client Id given to your Bonita installation. You can change it if you want but you need to provide it to your OIDC provider. -
auth-server-url
is the base URL of the OIDC provider server. All other service endpoints URL values can reuse this base URL with the placeholder{auth-server-url}
. -
auth-url
needs to be set with the URL of your OIDC provider Authorization endpoint. It can be prefixed with{auth-server-url}
to only indicate the path of the end point or be a full absolute URL. This property is specific to Bonita OIDC module and is not supported/documented by Keycloak. -
token-url
needs to be set with the URL of your OIDC provider Token endpoint. It can be prefixed with{auth-server-url}
to only indicate the path of the end point or be a full absolute URL. This property is specific to Bonita OIDC module and is not supported/documented by Keycloak. -
logout-url
needs to be set with the URL of your OIDC provider Logout endpoint. It can be prefixed with{auth-server-url}
to only indicate the path of the end point or be a full absolute URL. This property is specific to Bonita OIDC module and is not supported/documented by Keycloak. -
token-issuer-uri
needs to be set with the URL that will be used as issuer in the JWT tokens (iss
claim). It can be prefixed with{auth-server-url}
to only indicate the path of the issuer URI or be a full absolute URI. For example using Google’s OIDC provider, the issuer ishttps://accounts.google.com
. This property is specific to Bonita OIDC module and is not supported/documented by Keycloak. -
user-info-url
needs to be set with the URL of your OIDC provider userInfo end point. It is only used when accessing a resource with a BearerAuthorization
header with an access token that is opaque (not a JWT) and cannot be validated or used to retrieve the logged in user claims. It can be prefixed with{auth-server-url}
to only indicate the path of the end point or be a full absolute URL. This property is specific to Bonita OIDC module and is not supported/documented by Keycloak. -
jwks-url
needs to be set with the URL of your OIDC provider JSON Web Key Set endpoint. It can be prefixed with{auth-server-url}
to only indicate the path of the end point or be a full absolute URL. For example with Google as OIDC provider, this URL ishttps://www.googleapis.com/oauth2/v3/certs
. This property is specific to Bonita OIDC module and is not supported/documented by Keycloak. -
jwt-access-token
indicates if the access token is a JWT and should be validated. If false, it will be considered by Bonita OIDC module as an opaque token, its validation won’t be performed (but the ID token will, however, be validated) and the retrieval of the logged in user principal name will be delegated to the userInfo endpoint (seeuser-info-url
) when accessing a resource with a BearerAuthorization
header. Even if the access token is a JWT, this property should be set to false when the OIDC clients are not supposed/able to validate it. This property is specific to Bonita OIDC module and is not supported/documented by Keycloak. -
scope-values
can be used to set the value of thescope
parameter sent to the OIDC provider in the authentication request. The scope valueopenid
is automatically added if it is no present, but you can add other scope values likeemail
orprofile
depending on your OIDC provider configuration and the claims you need in the JWTs to match Bonita username. This property is specific to Bonita OIDC module and is not supported/documented by Keycloak. -
Some OpenID Connect providers do not support having a pattern of valid redirecting URIs. It is the case with Google’s for example. With those providers you can use the
state
parameter to pass the target URL (the URL you initially requested and want to be redirected to). In order to do that, set the propertysave-target-url-in-state
totrue
. When you do that, the redirect_URI query parameter will always be the same. Its default value is the path/bonita/keycloak
on Bonita server, but you can set a different value using the propertyredirect-uri-path
. Make sure this URL is part of the valid redirect URIs in you OIDC provider configuration for the Bonita client. Whensave-target-url-in-state
is set tofalse
or not present, theredirect_URI
query parameter is used to save the target URL. Those properties are specific to Bonita OIDC module and are not supported/documented by Keycloak. -
the
ssl-required
property value may need to be changed if Bonita Runtime and the IdP are not both accessed via HTTPS. Possible values for this property are:all
,external
, andnone
. Forall
, all requests must come in via HTTPS. Forexternal
, only non-private IP addresses must come over via HTTPS. Fornone
, no requests are required to come over via HTTPS (not recommended for production). For instance, using Azure AD as OIDC provider requires this property to be set toall
. -
the
principal-attribute
value indicates the OIDC Tokens attribute/claim to use to be considered as user identifier in the client application. It should match the username in Bonita. Supported values are:sub
,preferred_username
,email
,name
,nickname
,given_name
,family_name
. Using another value will result insub
claim being used. -
public-client
needs to be set tofalse
if the OIDC provider requires the client requests to be authenticated (with a client secret for example). In this case you also need to use thecredentials
property. If this property is set totrue
, then no client Authentication header will be sent to the OIDC provider. -
enable-cors
is required only if you want to be able to use Bonita REST API from a web application located on a different domain from your Bonita installation’s. It comes with additional optionscors-max-age
,cors-allowed-methods
,cors-allowed-headers
,cors-exposed-headers
. You can check Keycloak client adpter config documentation for more information. -
credentials
defines the authentication method used for token requests to the OIDC provider when Bonita client is configured with a confidential access type to the OIDC provider (public-client
is set tofalse
). You can set this property with an object containing just asecret
(in this caseclient_secret_basic
authentication method is used) or, since Bonita 2022.1-u6, you can specify the authentication method explicitly (for older versions see Keycloak’s client authentication documentation for the configuration of this property). Supported keys are:client-secret-basic
,client-secret-post
,client-secret-jwt
(orsecret-jwt
),private-key-jwt
(orjwt
). Here are some examples:"credentials" : { "secret" : "****" }
"credentials" : { "client-secret-post": { "secret" : "****" } }
"credentials" : { "client-secret-jwt": { "secret" : "****" "algorithm": "HS512" } }
"credentials" : { "private-key-jwt": { "client-keystore-file": "classpath:keystore-client.jks", "client-keystore-type": "JKS", "client-keystore-password": "storepass", "client-key-password": "keypass", "client-key-alias": "clientkey", "token-expiration": 10 } }
-
Some additional properties not present in the default file can be useful:
-
discovery-url
if the OIDC provider supports the OIDC discovery specification, this property can be used to configure the discovery endpoint URL (".well-known") to retrieve the provider’s endpoint locations (since Bonita 2022.1-u1). It can replace the 6 propertiesauth-url
,token-url
,logout-url
,token-issuer-uri
,user-info-url
andjwks-url
. This property is specific to Bonita OIDC module and is not supported/documented by Keycloak. -
connection-pool-size
for the pool of connection to the OIDC provider server (20 by default) -
truststore
path to a truststore file for OIDC provider servers requiring HTTPS. It should contain one or more trusted host certificates or certificate authorities. You can create this truststore by extracting the public certificate of the OIDC server’s SSL keystore. This property is mandatory if you OIDC provider requires HTTPS unless you setdisable-trust-manager
property totrue
. If the truststore requires a password, you also need to add the propertytruststore-password
. -
client-keystore
path to a keystore file containing client certificate for two-way SSL when the OIDC client adapter makes HTTPS requests to the OIDC provider server. You also need to add the propertiesclient-keystore-password
(password for the client keystore) andclient-key-password
(password for the client’s key). -
verify-token-audience
can be set totrue
to verify, when accessing the REST API with a Bearer authentication, that the access token audience (aud
claim) contains the client Id (resource
property). In Authorization Code Flow, this verification is always done and cannot be disabled. -
confidential-port
can be used to force the port in the redirect-uri sent to the OIDC provider when exchanging a code for a token (setting the value of this property to 443 when Bonita is accessed via HTTPS (ssl-required
is set toall
orexternal
) will result in the port not being added to the redirect-uri. This can help to avoid having a port 0 wrongly added to the redirect-uri). -
redirect-rewrite-rules
can be used to modify the path section of the redirect URI sent to the OIDC provider with the authentication or code exchange requests. By default the URI sent is the request URI as seen by Bonita OIDC module, but if Bonita is behind a reverse proxy for example, the path of the URI seen by Bonita OIDC module may be the one of the internal URI used by the reverse proxy and not the one of URI the OIDC provider needs to redirect the user agent (web browser) to. The value of this property is an object where each attribute key is a regular expression to which the Redirect URI path is to be matched and the attribute value is the replacement String. The other parts of the URI like the protocol, domain, port or query string cannot be modified. Here is an example removing "/bonita" from the redirect URI:"redirect-rewrite-rules" : { "^/bonita/(.*)$" : "/$1" }
-
-
More configuration options can be found in Keycloak official documentation |
Once your Identity Provider is correctly configured (see the section Configure the Identity Provider), try to access any Bonita Application page, an app page or a form URL (or just ?tenant=<tenantId>
) and make sure that you are redirected to your Identity Provider to log in (unless you are already logged in).
Note that if you try to access http://<bundle host>:<port>/bonita/login.jsp
, then you won’t be redirected to the OIDC provider’s authentication end point since this page needs to be accessible for the tenant administrator (or another user if you set the property oidc.auth.standard.allowed
to true
) to be able to log in without an account on the Identity Provider.
If your Bonita platform is behind a reverse proxy or a load balancer, You need to make sure : X-Forwarded-Proto: https X-Forwarded-Host: your.bonita.external.url.host In order for Tomcat server to use those headers, you can use Tomcat’s RemoteIpValve. Edit
In addition, you can add some log to diagnose received headers in
More information can be found in Tomcat offical documentation Remote_IP_Valve and Access_Log_Valve |
Configure the Identity Provider
Your OIDC identity provider (IdP) should declare an OIDC Service Provider named (or whose client Id is) bonita
(or the value of the resource
property set in the file keycloack-oidc.json of Bonita bundle if it is different ) with the following configuration or the equivalent depending on your IdP:
"clientId": "bonita", "clientSecret": "your client secret", "baseUrl": "<your bonita server URL>", (for example http://my.company.domain:8080/bonita) "adminUrl": "<your bonita server URL>/keycloak", (for example http://my.company.domain:8080/bonita/keycloak) this URL is used by the server to communicate directly with Bonita service provider (to push revocation policies for example)) "clientAuthenticatorType": "client-secret", (can also be "signed JWT" or "signed JWT with client secret" depending on your use case and security policies) "redirectUris": [ "http://my.company.domain:8080/*" (those are the valid redirect URLs) ], "bearerOnly": false, "publicClient": false, "consentRequired": false, (or true if you want the users to have to consent if a third party app uses Bonita REST API for example) "standardFlowEnabled": true, (this is for the authorization code flow) "implicitFlowEnabled": false, (Bonita OIDC module does not support implicit flow) "directAccessGrantsEnabled": true, (or false if you don't want to use the Resource Owner Credentials Grant type to access the REST API)
If you use "Signed JWT" as the method of authentication for your bonita client you must either provide the public key or the certificate of the Bonita server to the OIDC provider or a JWKS URL where the OIDC provider can download the client’s public keys. Bonita OIDC module provides this service at the following URL: "http://my.company.domain:8080/bonita/k_jwks"
You may also define some access or ID token signature and encryption mechanism. In this case, make sure to update Bonita bundle configuration file keycloack-oidc.json accordingly.
If the IdP declares a redirect URI, it might override the target URL ( |
Configure logout behaviour
If your Bonita platform is configured to manage authentication over OIDC, when users log out of Bonita Runtime, they do not log out of the OIDC Identity Provider (IdP). Therefore they are not logged out of all applications that are using the OIDC provider. To avoid this, you have two options :
Hide the logout button of the Bonita Layout
This is the most commonly used solution. Users are logged in as long as they don’t close their web browser and their session does not time out.
To do this, set the logout.link.hidden
option to true
in authenticationManager-config.properties
located in <BUNDLE_HOME>/setup/platform_conf/initial/tenant_template_portal
for not initialized platform or <BUNDLE_HOME>/setup/platform_conf/current/tenant_template_portal
and <BUNDLE_HOME>/setup/platform_conf/current/tenants/[TENANT_ID]/tenant_portal/
.
When a user logs out from the IdP directly, Bonita Runtime’s session will remain active. The user’s session time to live will be reset to the configured session timeout value upon each user interaction with the server. |
Setup Bonita platform for OIDC logout
RP-Initiated logout allows to log out from the OIDC provider as well as all the registered Service Providers when logging out from Bonita platform. This is required for example if users are on public computers. As OIDC Providers do not necessarily support OpenID logout and have different ways of handling it, Bonita only offers OIDC logout through an OIDC logout endpoint URL that the OIDC provider should provide and support. To setup Bonita for OIDC logout:
-
Set the value of the property
oidc.logout.url
with your OIDC provider logout endpoint URL inauthenticationManager-config.properties
located in<BUNDLE_HOME>/setup/platform_conf/initial/tenant_template_portal
for not initialized platform or<BUNDLE_HOME>/setup/platform_conf/current/tenant_template_portal
and<BUNDLE_HOME>/setup/platform_conf/current/tenants/<TENANT_ID>/tenant_portal/
. -
If the logout URL of your OIDC provider supports a parameter to redirect after the logout, you can set the property
oidc.logout.url.redirectQuery
with the query string to use (it will be concatenated to the logout URL). The placeholder{encodedRedirectUri}
will be replaced at runtime with the current Bonita URL at the time on the logout action. It is also possible to pass the ID token of the logged in user in the query string using the placeholder{idToken}
. This is useful if the OIDC provider supports theid_token_hint
parameter of the OIDC RP-Initiated logout specification (since Bonita 2022.1-u2). For this use case, make sure Bonita is configured for HTTPS since the ID token will be sent in the URL.
On the OIDC provider side, you need to configure Bonita OIDC service provider for:
-
either back-channel logout with the URL
<your bonita server URL>/keycloak/k_logout
(for example http://my.company.domain:8080/bonita/keycloak/k_logout) and a signature algorithm for the logout token (Logout JWT tokens must be signed). -
or front-channel logout with the URL
<your bonita server URL>/logoutservice/oidc
(for example http://my.company.domain:8080/bonita/logoutservice/oidc). Front-channel logout is only supported since Bonita 2022.1-u6. If Bonita and the OIDC provider are not on the same domain, you must make sure the provider adds the session ID (sid
) and issuer (iss
) parameters to the logout request and you also need to configure the file<BUNDLE_HOME>/setup/platform_conf/current/platform_portal/security-config.properties
to add the domain of the OIDC provider to the list of authorized frame-ancestors for Bonita applications (front channet logout request are sent in an Iframe by the OIDC provider) as follows:#Content-Security-Policy response header value bonita.runtime.security.csrf.header.content.security.policy=frame-ancestors 'self' https://my.company.oidc.provider:9090;
If the logout flow supported by your OIDC provider is not the same as the one supported by Bonita platform, the preferred solution to handle it anyway is to intercept the requests to /logoutservice and handle the logout programmatically.
Troubleshoot
To troubleshoot SSO login issues, you need to increase the log level to DEBUG
for the packages org.bonitasoft
, com.bonitasoft
, and TRACE
for org.keycloak
in order for errors to be displayed in the log files bonita.log
(by default, they are not).
In order to do that in a Tomcat bundle, you need to edit the file <BUNDLE_HOME>/server/conf/log4j2-loggers.xml
.
-
Make sure the following lines are not commented or add them if they are not present (the syntaxe of the line with
class org.keycloak
is necessary because of the way some of the loggers are created in Keycloak):
<Logger level="TRACE" name="org.keycloak"/>
<Logger level="TRACE" name="class org.keycloak"/>
-
Update the existing lines (to set the level to
DEBUG
):
<Logger level="DEBUG" name="org.bonitasoft"/>
<Logger level="DEBUG" name="com.bonitasoft"/>
Common error examples
Manage passwords
When your Bonita platform is configured to manage authentication over OIDC, the user password are managed in your OIDC Provider (IdP). However, when you create a user in Bonita Applications, specifying a password is mandatory. This password is ignored when logging in with the OIDC provider.
LDAP synchronizer and OIDC
If you are using an LDAP service and the LDAP synchronizer to manage your user data,
you can continue to do this and manage authentication over OIDC.
The LDAP synchronizer user must be registered in Bonita (no need for an OIDC account). It is recommended though to use the tenant admin account.
We recommend that you use LDAP as your master source for information, synchronizing the relevant information with your Bonita platform.
By default the LDAP synchronizer sets the password of the accounts created with the same value as the username. So, even if you allow standard authentication (by setting the property |
Using Bonita REST API with OIDC
When Bonita web application is configured for authentication with OpenID Connect, Bonita REST API is secured through OIDC too and it is possible to call it with just an OAuth Access token. This means "statelessness" as there is no need for a sticky session between the client and Bonita REST API. This is a major advantage if you want to use the REST API of a Bonita cluster of several nodes.
Authentication
To obtain the access token, there are several options depending on your OpenID Connect provider configuration and your use case:
Resource Owner Credentials Grant
In this scenario, the client application that needs to use Bonita REST API performs a request to the token end point of the OIDC provider with the username and password of the user account to use in Bonita.
For example, using a Keyclaok server as OIDC provider, with a realm named bonita
and a client Id bonitaOIDC
:
POST /auth/realms/bonita/protocol/openid-connect/token HTTP/1.1 Host: localhost:9090 Content-Type: application/x-www-form-urlencoded grant_type:password password:<user IdP password> username:<user IdP username> client_id:bonitaOIDC
The token endpoint of the OIDC provider will answer with an ID and an access token.
Once you obtained the Access token, you can make your REST API request in a normal way, just adding a header Authorization
with value Bearer <Access token>
(replace the placeholder <Access token> with the token returned by the OIDC provider and make sure to keep the whitespace after Bearer
).
Authorization Code Grant
Those scenarios work the same way as when you login into Bonita Runtime except, in this case, it is the client application that uses Bonita REST API which needs to trigger the authentication process by calling the OIDC provider authorization endpoint with Bonita OIDC client as client_id
. The rest of the scenario is similar to what is described in the OIDC Authorization Code Flow schema.
For example, if Bonita is configured to use Google’s OpenID Connect endpoint for authentication, then an application that wants to use Bonita REST API will need to delegate authentication to Google to obtain an authorization code for Bonita REST API.
With Authorization Code Flow, once you obtain the authorization code, you can request again the OIDC provider to get the tokens with as grant_type
value authorization_code
:
POST /auth/realms/bonita/protocol/openid-connect/token HTTP/1.1 Host: localhost:9090 Content-Type: application/x-www-form-urlencoded grant_type:authorization_code code:<your code from the OIDC response after user login/consent> client_id:<your client ID> client_secret:<your client secret>
The token endpoint of the OIDC provider will answer with an ID and an access token.
Once you obtained the Access token, you can make your REST API request in a normal way, just adding a header Authorization
with value Bearer <Access token>
.
If the OIDC provider returns opaque access token (non JWT), then Bonita OIDC client module will use UserInfo OIDC endpoint to validate the token and retrieve the user claims. Make sure the property |
CORS
If you want to call Bonita REST API from a page hosted on another domain than the one of the Bonita server, you need to enable Cross-Origin Resource Sharing (CORS) through Open ID Connect.
A limitation prevents CORS requests from working with Open ID Connect authentication in version 2021.2-u0 of Bonita. Please upgrade to 2021.2-u1 (or a more recent version) if you want to allow CORS through OIDC. |
Configure Bonita Bundle with OIDC for CORS
In the file keycloak-oidc.json, Make sure the property enable-cors
is set to true and the properties cors-allowed-methods
, cors-allowed-headers
, cors-exposed-headers
have the correct values. For a basic configuration, you can use the following values:
"enable-cors": true, "cors-allowed-methods": "GET,HEAD,POST,PUT,DELETE", "cors-allowed-headers": "content-type,X-Requested-With,accept,Origin,Access-Control-Request-Method,Access-Control-Request-Headers,x-bonita-api-token,authorization", "cors-exposed-headers": "Access-Control-Allow-Origin,Access-Control-Allow-Credentials,x-bonita-api-token,content-type",
You don’t need to configure any additional CORS filter (which is the way to handle CORS when Bonita web application is not configured for Authentication with OIDC). Also make sure to update the sameSiteCookies policy of the Tomcat server and use HTTPS on your Bonita server.
Configure the Identity Provider
In your OIDC identity provider (IdP) configuration, you should make sure the bonita
OIDC Service Provider declares the URLs of the domains where the pages requiring calls to Bonita REST API are hosted (or *
if you want to allow all origins) as Allowed CORS web origins
.